SENSOFIT FLOW 1000 Y

Flow-through assembly for chemical and water treatment applications

  • For use with Ø12 / 120 mm sensors (pH, ORP, Cl) or conductive conductivity sensors
  • Sensor connection: PG13.5, G¾ (female); Process connection: G1 (female)
  • For inline measurement at 180°Flow direction
  • Max. +95°C / +203°F and 10 bar / 145 psi

SENSOFIT FLOW 1000 Y

Flow-through assembly for chemical and water treatment applications

  • For use with Ø12 / 120 mm sensors (pH, ORP, Cl) or conductive conductivity sensors
  • Sensor connection: PG13.5, G¾ (female); Process connection: G1 (female)
  • For inline measurement at 180°Flow direction
  • Max. +95°C / +203°F and 10 bar / 145 psi

Related products

SMARTPAT PH 8150

Potentiometric pH sensor for chemicals and industrial wastewater applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • 0…14 pH; Max. +130°C / +266°F; 12 bar / 174 psi
  • Glass sensor with open diaphragms and Pt1000 for temperature compensation

SMARTPAT PH 8320

Potentiometric pH sensor for water and wastewater applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • 0…14 pH; Max. +70°C / +158°F; 10 bar / 145 psi
  • Glass sensor with PTFE diaphragm and Pt1000 for temperature compensation

SMARTPAT PH 8530

Potentiometric pH sensor for pure water and low conductivity media (>2 μS/cm)

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • 0…14 pH; Max. +80°C / +176°F; 12 bar / 174 psi
  • Glass sensor with 3 ceramic diaphragms and Pt1000 for temperature compensation

SMARTPAT PH 8570

Potentiometric pH sensor for food, beverage and pharmaceutical applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • 0…14 pH; Max. +140°C / +284°F (SIP/CIP); 12 bar / 174 psi
  • Autoclavable glass sensor with ceramic diaphragm and Pt1000 for temperature compensation

SMARTPAT ORP 8150

Potentiometric ORP sensor for chemicals and industrial wastewater applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • -1500…+1500 mV; Max. +130°C / +266°F; 12 bar / 174 psi
  • Glass sensor with platinum electrode, open diaphragm and Pt1000 temperature sensor

SMARTPAT ORP 8510

Potentiometric ORP sensor for water and wastewater applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • -1500…+1500 mV; Max. +70°C / +158°F; 2 bar / 30 psi
  • Glass sensor with platinum electrode, ceramic diaphragm and Pt1000 temperature sensor

SMARTPAT COND 1200

Conductive conductivity sensor for water and wastewater applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: G¾ (male)
  • 0.1…20 mS/cm; Max. +135°C / +275°F; 16 bar / 232 psi
  • With stainless steel electrodes and Pt1000 for temperature compensation

OPTISENS PH 8100

Potentiometric pH sensor for chemicals, industrial wastewater and low conductivity media (>2 μS/cm)

  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +130°C / +266°F; 10 bar / 145 psi
  • Glass sensor with 2 open diaphragms and Pt100 for temperature compensation

OPTISENS PH 8300

Potentiometric pH sensor for wastewater, surface and process water applications

  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +70°C / +158°F; 10 bar / 145 psi
  • Glass sensor with PTFE diaphragm and optional Pt100 for temperature compensation

OPTISENS PH 8500

Potentiometric pH sensor for potable water applications

  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +70°C / +158°F; 2 bar / 30 psi
  • Glass sensor with ceramic diaphragm and optional Pt100 for temperature compensation

OPTISENS PH 9100

Potentiometric pH sensor for lower conductivity water applications (>20 μS/cm)

  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +100°C / +212°F; 1 bar / 14 psi
  • Liquid electrolyte glass sensor with open glass sleeve diaphragm

OPTISENS PH 9500

Potentiometric pH sensor for lower conductivity water applications (>50 μS/cm)

  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +100°C / +212°F ; 1 bar / 14 psi
  • Liquid electrolyte glass sensor with 3 ceramic diaphragms

OPTISENS ORP 8500

Potentiometric ORP sensor for water and wastewater applications

  • For use with analytical transmitter
  • Process connection: PG13.5
  • -1500…+1500 mV; Max. +70°C / +158°F; 2 bar / 30 psi
  • Glass sensor with platinum electrode and ceramic diaphragm

OPTISENS COND 1200

Conductive conductivity sensor for water, wastewater, process water or pure water

  • For use with analytical transmitter
  • Process connection: G½, G¾, G1, ¾ NPT (male)
  • 0.05 μS/cm…20 mS/cm; Max. +135°C / +275°F
  • With two stainless steel, titanium or graphite electrodes and Pt100 for temperature compensation

OPTISENS CL 1100

Potentiostatic amperometric disinfectant sensor for water and wastewater applications

  • For use with MAC 100 analytical transmitter
  • Process connection: PG13.5
  • Cl2: 0.03…20 mg/l; ClO2: 0.05…5  mg/l; O3: 0.05…5 mg/l; Max. +70°C / +158°F; 6 bar / 87 psi
  • Membrane-free sensor with 2 gold electrodes and sensor cleaning feature
Email